  • Reznor AB LPHW Series Industrial Air Curtain
SALE

Reznor AB LPHW Series Industrial Air Curtain 60kW - 210kW

Reznor
  • 60kW - 210kW Heat Output
  • 230V - 3-Phase Power
  • Reduces Environment Temperature Loss
  • Optional Fan Speed Control
  • Remote Control Panels
  • Exceptionally Energy-Efficient
Price Match
Rapid Delivery
Low Stock
1 Year Warranty
£5,805.00
£5,399.80
£6,479.76 (inc VAT)
Visa accepted Master Card accepted PayPal pay accepted Pay by Bank accepted BACS payments accepted

Call FREE for expert advice

0808 196 9380

Features

Nine Models: From a range of door widths from 2 metres to 6.7 metres. All are suitable for doorways up to six metres high.

Diverse Power Options: Options are available forNatural gas (G20) or propane (G31) operated models. This range also others Ambient, LPHW, Gas and electric heated variants.

Versatile Instillation Options: Standard units are suitable for horizontal mounting over the top of a door. For applications requiring vertical air curtains special ‘tailor made’ units are available.

Energy Efficient: Air curtains provided a cost-efficient means of temperature control ensuring consistent environmental heating standards and thus a minimal need for prolonged use of standard heaters.

Operate in Conjunction with Conventional Heating Systems: These units compliment standard heating systems. Once a building’s built-in heating system has manufactured a desired temperature level, the air curtain system can maintain this with minimal temperature loss through air temperature seepage. Heated Units can also operate when doors are closed providing supplementary heating.

Minimal Loss of Environmental Temperatures: The AB Series creates an air curtain so effective that egress point can be kept open for more efficient building access and foot flow while minimising temperature seepage through these open areas.

Ease of Handling: Models are delivered in a modular format ensuring a seamless ability to transport the device to its required instillation location.

Remote Control Panels: These panels provide extensive functionality to the operation of the machine.

Optional Fan Speed Control: Are available for all models in the range as an added extra.

Description

Reznor AB Series Industrial Air Curtains

Energy Efficiency, Cost Efficient, Temperature Regulation Unit

The AB series of air curtains provide a barrier of high velocity air flow that helps to negate the seepage of hot air out & cold air in through open egress points. Perfectly suited for installation over or along a door or window these units push waves of heated air across the surface area of the egress point. This creates a heat-sealing barrier that helps to regulate building temperatures.
For best operational functionality the air curtain should be mounted horizontally above the door to enable rising warm air to be re-circulated to lower levels. Units are available that can be vertically mounted at one or both sides of the door if above door installation is not possible.
This is a versatile range that offers a wide variety of variations to suit your requirements. Maximum door widths range from 1750 mm, 2250mm, 3500mm, 4000mm, 4500mm, 5250mm, 5750mm, 6250mm, 6750mm, depending on unit purchased. All units in the range are suitable for doorways up to six metres high.
The AB series also offers one of the most diverse arrays of heat capacity options. Hot water units range from 60kW, 70kW, 120kW, 130, 140kW, 180kW, 190kW, 200kW, 210kW. Unit may be operational using Natural gas (G20) or propane (G31) depending on model purchased.
All Reznor units in this series incorporate the following design features for optimum performance. Uniform linear flow across the full door width. Fan speed control with extra width adjustable air jet for improved wind resistance.


See More Like This: Air Curtains

Specification

Model AB175-2
Maximum door width mm 1750
Maximum mounting height mm 6000
Number of modules 1
Number of fans 3
Maximum air volume m3/h 11000
Maximum heating capacity
Hot water kW 60
Electrical supply V 230V 1 ph 50 Hz
Current rating per fan A 5.2 full load current

Model AB225-2
Maximum door width mm 2250
Maximum mounting height mm 6000
Number of modules 1
Number of fans 4
Maximum air volume m3/h 13000
Maximum heating capacity
Hot water kW 70
Electrical supply V 230V 1 ph 50 Hz
Current rating per fan A 5.2 full load current

Model AB350-2
Maximum door width mm 3500
Maximum mounting height mm 6000
Number of modules 2
Number of fans 6
Maximum air volume m3/h 22000
Maximum heating capacity
Hot water kW 120
Electrical supply V 415V 3 ph 50 Hz
Current rating per fan A 5.2 full load current

Model AB400-2
Maximum door width mm 4000
Maximum mounting height mm 6000
Number of modules 2
Number of fans 7
Maximum air volume m3/h 24000
Maximum heating capacity
Hot water kW 130
Electrical supply V 415V 3 ph 50 Hz
Current rating per fan A 5.2 full load current

Model AB450-2
Maximum door width mm 4500
Maximum mounting height mm 6000
Number of modules 2
Number of fans 8
Maximum air volume m3/h 26000
Maximum heating capacity
Hot water kW 140
Electrical supply V 415V 3 ph 50 Hz
Current rating per fan A 5.2 full load current

Model AB525-2
Maximum door width mm 5250
Maximum mounting height mm 6000
Number of modules 3
Number of fans 9
Maximum air volume m3/h 33000
Maximum heating capacity
Hot water kW 180
Electrical supply V 415V 3 ph 50 Hz
Current rating per fan A 5.2 full load current

Model AB575-2
Maximum door width mm 5750
Maximum mounting height mm 6000
Number of modules 3
Number of fans 10
Maximum air volume m3/h 35000
Maximum heating capacity
Hot water kW 190
Electrical supply V 415V 3 ph 50 Hz
Current rating per fan A 5.2 full load current

Model AB625-2
Maximum door width mm 6250
Maximum mounting height mm 6000
Number of modules 3
Number of fans 11
Maximum air volume m3/h 37000
Maximum heating capacity
Hot water kW 200
Electrical supply V 415V 3 ph 50 Hz
Current rating per fan A 5.2 full load current

Model AB675-2
Maximum door width mm 6750
Maximum mounting height mm 6000
Number of modules 3
Number of fans 12
Maximum air volume m3/h 39000
Maximum heating capacity
Hot water kW 210
Electrical supply V 415V 3 ph 50 Hz
Current rating per fan A 5.2 full load current

Customer Reviews

There are currently no reviews for this item, why not be the first?

×

PAYPAL PAY IN 3

SPREAD THE COST OF ESSENTIAL HEATING, VENTILATION, AND AIR CONDITIONING EQUIPMENT

Whether you need a long-term, short-term, or temporary climate solution, sometimes it can help if you can break the costs down, especially if the situation is unexpected or an emergency.

To help our customers and make climate control and air quality equipment more accessible, we've worked with PayPal to provide a way to spread the cost with PayPal Pay in 3. You can use Pay in 3 for eligible shopping cart amounts between £30.00 to £2,000.00. Terms apply.

×

LIGHTNING DEAL